Ventilation Calculator

How to Calculate

Step 1: Measure

Measure the length and width of the attic floor space to be ventilated.

Step 2: Calculate

Enter the length and width or the total square footage of the attic floor space to be ventilated.
Check Mark in Badge Icon

Step 3: Identify

See recommended quantities below for each GAF Ventilation Product (typically rounded up).

Let’s get started

Use this calculator to help determine the proper amount of attic ventilation based on U.S. FHA 1/300 guidelines.*

Please choose an address from the list or your address won’t be submitted.
Enter your measurements below.
Please enter a valid number
Please enter a valid number

Or

Please enter a valid number

Suggestions for 900 sq. ft. Area

Numbers shown represent the recommended total number of units required for a single product.
384 Minimum Sq. In. of Net Free Area of exhaust needed at or near the ridge.
And
384 Minimum Sq. In. of Net Free Area of intake needed at or near the soffit.

Please Note:

Some local building codes require the 1/150 attic ventilation rule, which increases the minimum attic ventilation needed. Always consult local building code requirements in your area for details.
Note: N/R = not recommended

Exhaust Ventilation

ProductLineal Feet Required
Cobra® RidgeRunner®31'
Cobra® Rigid Vent 322'
Cobra® SnowCountry®22'
Cobra® SnowCountry® Advanced22'
Cobra® Hip Vent43'
TruSlate® Ridge Vent43'

Product

Cobra® RidgeRunner®

Lineal Feet Required

31'

Product

Cobra® Rigid Vent 3

Lineal Feet Required

22'

Product

Cobra® SnowCountry®

Lineal Feet Required

22'

Product

Cobra® SnowCountry® Advanced

Lineal Feet Required

22'

Product

Cobra® Hip Vent

Lineal Feet Required

22'

Product

TruSlate® Ridge Vent

Lineal Feet Required

22'

ProductLineal Feet Required
Cobra® Exhaust Vent - Hand Nailable31'
Cobra® Exhaust Vent - Nail Gunnable22'

Product

Cobra® Exhaust Vent - Hand Nailable

Lineal Feet Required

31'

Product

Cobra® Exhaust Vent - Nail Gunnable

Lineal Feet Required

22'

ProductLineal Feet Required
AR1031'

Product

AR10

Lineal Feet Required

31'

ProductNumber Required
RT65 Plastic Square - Top31
IR61 Plastic Slant - Back31
R50/RV50 Metal Utility31
IR65 Plastic Slant - Back31
SSB960 Metal Super Slant - Back31
HCD144 High-Capacity Dome Vent31

Product

RT65 Plastic Square - Top

Number Required

31

Product

IR61 Plastic Slant - Back

Number Required

31

Product

R50/RV50 Metal Utility

Number Required

31

Product

IR65 Plastic Slant - Back

Number Required

31

Product

SSB960 Metal Super Slant - Back

Number Required

31

Product

HCD144 High-Capacity Dome Vent

Number Required

31

Intake Ventilation

ProductLineal Feet Required
Cobra IntakePro®31'

Product

Cobra IntakePro®

Lineal Feet Required

31'

Product

Cobra® Fascia Vent (Mesh Roll) 1"

Lineal Feet Required

22'

Product

Cobra® Fascia Vent (Mesh Roll) 1.5"

Lineal Feet Required

22'

ProductNumber Required
LSV8 Metal Continuous Soffit Vents (Lineal Feet)31'
EAP 4x12 Plastic Soffit Vents31
EAC 16x4 Metal Soffit Vents31
EAC 16x8 Metal Soffit Vents31
EmberShield® Closeable Soffit Vents31

Product

LSV8 Metal Continuous Soffit Vents

Number Required

31

Product

EAP 4x12 Plastic Soffit Vents

Number Required

22

Product

EAC 16x4 Metal Soffit Vents

Number Required

22

Product

EAC 16x8 Metal Soffit Vents

Number Required

22

Product

EmberShield® Closeable Soffit Vents

Number Required

22

Intake or Exhaust Ventilation

Note: Gable louvers are typically installed in pairs

ProductNumber Required
DA 12x1231
DA 12x1831
DA 14x2431
DA 18x2431
DA 24x3031

Product

DA 12x12

Number Required

31

Product

DA 12x18

Number Required

31

Product

DA 14x24

Number Required

31

Product

DA 18x24

Number Required

32

Product

DA 24x30

Number Required

33

ProductNumber Required
SL 8x831
SL 12x1231
SL 12x1831
SL 18x2431

Product

SL 8x8

Number Required

34

Product

SL 12x12

Number Required

35

Product

SL 12x18

Number Required

36

Product

SL 14x24

Number Required

37

Product

SL 18x24

Number Required

38

ProductNumber Required
RLSC 2"31
RLSC 3"31
RLSC 4"31

Product

RLSC 2"

Number Required

39

Product

RLSC 3"

Number Required

40

Product

RLSC 4"

Number Required

41

Exhaust Ventilation

ProductNumber Required
ERV431
ERV5 & Wi-Fi ERV5QCT22
ERV622
EZ Cool EZCR122

Product

ERV4

Number Required

31

Product

ERV5 & Wi-Fi ERV5QCT

Number Required

22

Product

ERV6

Number Required

31

Product

EZ Cool EZCR1

Number Required

31

ProductNumber Required
EGV5 & Wi-Fi EGV5QCT31
EGV622
EZ Cool EZCG122

Product

EGV5 & Wi-Fi EGV5QCT

Number Required

31

Product

EGV6

Number Required

31

Product

EZ Cool EZCG1

Number Required

31

ProductNumber Required
Solar & Dual-Powered Roof (ERVSOLAR / ERVHYBRID)31
Solar-Powered Gable (PGSOLAR)22
High-Power Solar & Dual-Powered Roof (PRSOLAR2 / PRHYBRID2)22

Product

Solar & Dual-Powered Roof (ERVSOLAR / ERVHYBRID)

Number Required

31

Product

Solar-Powered Gable (PGSOLAR)

Number Required

31

Product

High-Power Solar & Dual-Powered Roof (PRSOLAR2 / PRHYBRID2)

Number Required

31

ProductNumber Required
12"31
14"22

Product

12"

Number Required

31

Product

14"

Number Required

31

Intake Ventilation

ProductLineal Feet Required
with ERV431'
with ERV5 & Wi-Fi ERV5QCT22'
with ERV631'
with EZ Cool EZCR131'
with EGV5 & Wi-Fi EGV5QCT22'
with EGV631'
with EZ Cool EZCG131'
with Solar & Dual-Powered Roof22'
with Solar-Powered Gable22'
with High-Power Solar & Dual-Powered Roof22'
with 12" Wind Turbine22'
with 14" Wind Turbine22'

Product

with ERV4

Lineal Feet Required

31'

Product

with ERV5 & Wi-Fi ERV5QCT

Lineal Feet Required

31'

Product

with ERV6

Lineal Feet Required

31'

Product

with EZ Cool EZCR1

Lineal Feet Required

31'

Product

with EGV5 & Wi-Fi EGV5QCT

Lineal Feet Required

31'

Product

with EGV6

Lineal Feet Required

31'

Product

with EZ Cool EZCG1

Lineal Feet Required

31'

Product

with Solar & Dual-Powered Roof

Lineal Feet Required

31'

Product

with Solar-Powered Gable

Lineal Feet Required

31'

Product

with High-Power Solar & Dual-Powered Roof

Lineal Feet Required

31'

Product

with 12" Wind Turbine

Lineal Feet Required

31'

Product

with 14" Wind Turbine

Lineal Feet Required

31'

ProductLineal Feet Required
with ERV431'
with ERV5 & Wi-Fi ERV5QCT22'
with ERV631'
with EZ Cool EZCR131'
with EGV5 & Wi-Fi EGV5QCT22'
with EGV631'
with EZ Cool EZCG131'
with Solar & Dual-Powered Roof22'
with Solar-Powered Gable22'
with High-Power Solar & Dual-Powered Roof22'
with 12" Wind Turbine22'
with 14" Wind Turbine22'

Product

with ERV4

Lineal Feet Required

31'

Product

with ERV5 & Wi-Fi ERV5QCT

Lineal Feet Required

31'

Product

with ERV6

Lineal Feet Required

31'

Product

with EZ Cool EZCR1

Lineal Feet Required

31'

Product

with EGV5 & Wi-Fi EGV5QCT

Lineal Feet Required

31'

Product

with EGV6

Lineal Feet Required

31'

Product

with EZ Cool EZCG1

Lineal Feet Required

31'

Product

with Solar & Dual-Powered Roof

Lineal Feet Required

31'

Product

with Solar-Powered Gable

Lineal Feet Required

40'

Product

with High-Power Solar & Dual-Powered Roof

Lineal Feet Required

31'

Product

with 12" Wind Turbine

Lineal Feet Required

31'

Product

with 14" Wind Turbine

Lineal Feet Required

31'

ProductNumber Required
with ERV431
with ERV5 & Wi-Fi ERV5QCT22
with ERV631
with EZ Cool EZCR131
with EGV5 & Wi-Fi EGV5QCT22
with EGV631
with EZ Cool EZCG131
with Solar & Dual-Powered Roof22
with Solar-Powered Gable22
with High-Power Solar & Dual-Powered Roof22
with 12" Wind Turbine22
with 14" Wind Turbine22

Product

with ERV4

Number Required

31

Product

with ERV5 & Wi-Fi ERV5QCT

Number Required

31

Product

with ERV6

Number Required

31

Product

with EZ Cool EZCR1

Number Required

31

Product

with EGV5 & Wi-Fi EGV5QCT

Number Required

31

Product

with EGV6

Number Required

31

Product

with EZ Cool EZCG1

Number Required

31

Product

with Solar & Dual-Powered Roof

Number Required

31

Product

with Solar-Powered Gable

Number Required

49

Product

with High-Power Solar & Dual-Powered Roof

Number Required

31

Product

with 12" Wind Turbine

Number Required

31

Product

with 14" Wind Turbine

Number Required

31

ProductNumber Required
with ERV431
with ERV5 & Wi-Fi ERV5QCT22
with ERV631
with EZ Cool EZCR131
with EGV5 & Wi-Fi EGV5QCT22
with EGV631
with EZ Cool EZCG131
with Solar & Dual-Powered Roof22
with Solar-Powered Gable22
with High-Power Solar & Dual-Powered Roof22
with 12" Wind Turbine22
with 14" Wind Turbine22

Product

with ERV4

Number Required

31

Product

with ERV5 & Wi-Fi ERV5QCT

Number Required

31

Product

with ERV6

Number Required

31

Product

with EZ Cool EZCR1

Number Required

31

Product

with EGV5 & Wi-Fi EGV5QCT

Number Required

31

Product

with EGV6

Number Required

31

Product

with EZ Cool EZCG1

Number Required

31

Product

with Solar & Dual-Powered Roof

Number Required

31

Product

with Solar-Powered Gable

Number Required

58

Product

with High-Power Solar & Dual-Powered Roof

Number Required

31

Product

with 12" Wind Turbine

Number Required

31

Product

with 14" Wind Turbine

Number Required

31

ProductNumber Required
with ERV431
with ERV5 & Wi-Fi ERV5QCT22
with ERV631
with EZ Cool EZCR131
with EGV5 & Wi-Fi EGV5QCT22
with EGV631
with EZ Cool EZCG131
with Solar & Dual-Powered Roof22
with Solar-Powered Gable22
with High-Power Solar & Dual-Powered Roof22
with 12" Wind Turbine22
with 14" Wind Turbine22

Product

with ERV4

Number Required

31

Product

with ERV5 & Wi-Fi ERV5QCT

Number Required

31

with ERV6

Number Required

31

with EZ Cool EZCR1

Number Required

31

with EGV5 & Wi-Fi EGV5QCT

Number Required

31

with EZ Cool EZCG1

Number Required

31

with Solar & Dual-Powered Roof

Number Required

31

with Solar-Powered Gable

Number Required

67

with High-Power Solar & Dual-Powered Roof

Number Required

31

with 12" Wind Turbine

Number Required

31

with 14" Wind Turbine

Number Required

31

ProductNumber Required
with ERV431
with ERV5 & Wi-Fi ERV5QCT22
with ERV631
with EZ Cool EZCR131
with EGV5 & Wi-Fi EGV5QCT22
with EGV631
with EZ Cool EZCG131
with Solar & Dual-Powered Roof22
with Solar-Powered Gable22
with High-Power Solar & Dual-Powered Roof22
with 12" Wind Turbine22
with 14" Wind Turbine22

Product

with ERV4

Number Required

31

Product

with ERV5 & Wi-Fi ERV5QCT

Number Required

31

Product

with ERV6

Number Required

31

Product

with EZ Cool EZCR1

Number Required

31

Product

with EGV5 & Wi-Fi EGV5QCT

Number Required

31

Product

with EGV6

Number Required

31

Product

with EZ Cool EZCG1

Number Required

31

Product

with Solar & Dual-Powered Roof

Number Required

31

Product

with Solar-Powered Gable

Number Required

75

Product

with High-Power Solar & Dual-Powered Roof

Number Required

31

Product

with 12" Wind Turbine

Number Required

31

Product

with 14" Wind Turbine

Number Required

31

Diagram of intake and exhaust ventilation

The 1/300 balanced attic ventilation rule

Proper attic ventilation consists of a balance between air intake (at or near your soffits) and air exhaust (at or near your roof ridge). The U.S. Federal Housing authority recommends a minimum of 1 square foot of attic ventilation (evenly split between intake and exhaust) for every 300 square feet of attic floor space. Always have a balanced ventilation system. In no case should the amount of exhaust ventilation exceed the amount of intake ventilation.
*Note: The 1/300 rule is a general rule and does not apply to all situations. Local building codes, when stricter, take precedence. Always consult a design professional for cathedral ceilings, insulated roof decks, etc.
Examples of static, power, and mechanical attic vents

Learn about attic vent options

Are you confused about the many attic ventilation solutions available? Curious why one roof would get ridge ventilation and another would incorporate power vents or a roof louver? Watch this video for a great introduction to the art and science of choosing the right attic ventilation components for your roof.

Your top attic ventilation questions answered

Image showing why you should use attic ventilation

How to Ventilate an Attic - How Attic Ventilation Works | GAF Roofing

What is attic ventilation? Learn how attics are ventilated.
How to Select Products for Your Attic Ventilation System

How to Select Products for Your Attic Ventilation System | GAF Roofing

Determine which ventilation products are best for your roofing project.
video for how to plan a balanced attic ventilation system

How to Plan a Balanced Attic Ventilation System | GAF Roofing Materials

In this video, you will learn how to calculate a balanced attic ventilation system.
Home with ventilation arrows

How to Avoid Common Attic Ventilation Installation Mistakes | GAF Roofing

When planning and installing a balanced attic ventilation system, it is important to understand and avoid these common mistakes that may reduce the effectiveness of the system.

Related Articles

GAF Timberline HDZ Reflector Series Shingles on a roof.
Residential Roofing

Timberline HDZ® Reflector Series Shingles: A New Era in Reflective Shingles

GAF Timberline HDZ® Reflector Series Shingles come in rich, vibrant colors, giving homeowners attractive color options that can be used to comply with the Cool Roof Requirements of Title 24 and the LA County Green Building Standards Code.*Here's why you may want to add these shingles to your business offerings, especially if you work in California.Timberline HDZ® RS ShinglesA few features make these shingles stand out.Meeting California Code ComplianceIn California, residential roofs must meet solar reflectance requirements because they are mandated by California's Building Energy Efficiency Standards Title 24, Part 6 and Los Angeles County Green Building Code. Both codes set a minimum reflectance rating known as the solar reflective index (SRI), which measures a material's ability to reflect sunlight and heat. The lower the SRI value (from 0 to 100), the hotter a material becomes in sunlight. The higher the value, the cooler the material. Shingles with a higher SRI help reduce temperatures by reflecting sunlight which can help reduce the cooling load.The new Timberline HDZ® RS Shingles provide solar reflectance that complies with both Title 24 and the Los Angeles County Green Building Code.Title 24California's Title 24 covers the entire state, unless local requirements are stricter, providing cool roof requirements for residential and commercial buildings based on their locations within 16 climate zones. For residential buildings (new construction), climate zones 1 through 9 and 16 have no cool roof requirements. Climate zones 4, and 8 through 15 require cool roofs for new and reroof applications when more than 50% of the roof is removed.If shingles don't meet the required SRI, alternative paths to compliance include using a radiant barrier, airspace, or additional attic insulation.Los Angeles County Green Building CodeThe Los Angeles County Green Building Code's Cool Roof Ordinance covers buildings in the county and prescribes SRI values depending on the type of building (low-rise residential, high-rise residential and hotels/motels, and nonresidential) and roof slope. High-slope (more than 2:12), low-rise residential roofs must have an SRI of 20 or more. Exceptions apply to roof repairs or replacements where less than 50% of the roof is removed, additions of less than 500 square feet or less than 50% of the total roof area, and green roofs.Selling Points for California HomeownersWhen working with property owners in California and Los Angeles County, you can highlight the following selling points of Timberline HDZ® Reflector Series Shingles.Potential Savings on Cooling CostsReflective roofing may help decrease a roof's temperature and cooling load, which has the potential to lower cooling costs.****StyleTimberline HDZ® RS Shingles provide the darkest highly-reflective shingle available, Charcoal, thanks to EcoDark® granules. They also feature GAF's High Definition® color blends for dimensional, wood-shake look.Peace of MindHomeowners can enjoy heightened confidence when choosing Timberline HDZ® RS Shingles because they come with a Lifetime Limited Warranty***** against manufacturing defects and a 25-year StainGuard Plus™ Algae Protection limited warranty.**Enhancing Homes' AppealHomeowners can rest assured that the new Timberline HDZ® Reflector Series Shingles offer the durability of GAF shingles while providing deep, rich color options to match their unique aesthetic.Color OptionsTimberline HDZ® RS shingles feature newly formulated EcoDark® Granules that provide deep rich, dark colors including Charcoal, the darkest highly-reflective shingle color in California, as well as other popular shingle colors that offer color blends for a more dimensional look.Time-Release Algae Fighting TechnologyTimberline HDZ® RS shingles feature GAF Time-Release Algae-Fighting Technology which uses specially engineered capsules that are infused with thousands of copper microsites. This allows the copper to release steadily over time for long-lasting algae fighting power. It's technology so strong, it powers the 25-Year StainGuard Plus™ Algae Protection Limited Warranty.**WindProven Limited Wind WarrantyTimberline HDZ® RS shingles have LayerLock® technology and the StrikeZone™, nailing area like traditional Timberline HDZ® shingles, and are eligible for the WindProven™ Limited Wind Warranty with no maximum wind speed limitation when installed with the required combination of accessories.***Curious to learn more? Visit the GAF Timberline HDZ® RS Shingles product page for more details.*Can be used to comply with the Cool Roof Requirements for steep slope residential buildings of 2022 Title 24, Part 6, of the California Code of Regulations and the Green Building Standards Code of Los Angeles County.**25-year StainGuard Plus Algae Protection Limited Warranty against blue-green algae discoloration is available only on products sold in packages bearing the StainGuard Plus logo. See GAF Shingle and Accessory Limited Warranty for complete coverage and restrictions.***15-year WindProven™ limited wind warranty covers GAF Shingles with LayerLock® Technology only and requires the use of GAF Starter Strips, Roof Deck Protection, Ridge Cap Shingles, and Leak Barrier or Attic Ventilation. See GAF Roofing System Limited Warranty for complete coverage and restrictions. Visit gaf.com/LRS for qualifying GAF products. For installations not eligible for the WindProven limited wind warranty, see GAF Shingle & Accessory Limited Warranty for complete coverage and restrictions.****Energy cost savings are not guaranteed and the amount of savings may vary based on a variety of factors, such as climate zone, utility rates, radiative properties of roofing products, insulation levels and HVAC equipment efficiency.*****Definition of Lifetime: The word "Lifetime" means as long as you, the original owner(s) [or the second owner(s) if coverage was properly transferred during the Smart Choice Protection Period], own the property where the shingles and/or accessories are installed. The Lifetime warranty is applicable only to shingles and accessories installed on a single-family detached residence owned by individuals. For any other type of owner or building, such as a corporation, governmental entity, religious entity, condominium or homeowner association, school, apartment building, office building, or multi-use structure, the length of the warranty is 40 years. See the GAF Shingle & Accessory Limited Warranty, GAF Roofing System Limited Warranty and GAF Golden Pledge Limited Warranty for complete coverage and restrictions.

By Authors Dawn Killough

September 06, 2024

A roofer installs GAF's Cobra SnowCountry Advanced Premium Exhaust Vent on a Roof Ridge
Residential Roofing

The Role of Roofing Codes and Standards in Roof Venting Product Development

When developing a new roofing product, it's important to ensure it meets the local roofing codes and requirements in multiple jurisdictions. These standards are often regionally similar, but some may require additional testing or the use of certain raw materials. The product development team at GAF works hard to ensure products meet some of the strictest codes, so they can provide years of protection no matter where they're installed.Jeremiah Hershberger, GAF product manager of residential accessories, recently discussed the role codes and standards play in residential roofing product development, specifically concerning roof vent code requirements.Why Are Product Codes and Standards Important?The main purpose of building codes and standards is to maintain public health, safety, and welfare in all structures. They do this by ensuring that buildings are constructed in such a way as to minimize potential hazards, like fire, structural failure, or storm damage.Building codes exist to improve the safety and livability of buildings. They set minimum requirements for the materials and systems installed, as well as their installation methods. In the US, building codes are upheld and enforced by state, county, and city governments through the permitting and inspection processes.Standards also provide minimum design and performance metrics for products and systems. However, unlike local building codes, they are often universally upheld (nationally or worldwide). Organizations like ASTM International and the National Fire Protection Association are responsible for creating, updating, and communicating these standards. Local building codes often use these standards to set minimums for product and installation quality.How Do Roofing Codes and Standards Affect Product Development?"The goal of product development at GAF is to provide enhanced value for our customers and contractors," Hershberger explains. Ultimately, customers need to be confident in the performance of GAF products and building codes and standards provide a minimum threshold for product performance. Accordingly, they must be taken into consideration when designing products.Codes are prescriptive performance requirements for buildings. They include both the materials used to construct the building and how they're installed. All products used in a particular building must meet the local code requirements for that county or city.Standards are used as bases of comparison. Types of standards include:Testing standards that define methods and minimum acceptable resultsRating standards that provide a way to fairly compare productsDesign standards that set the criteria for specific roof system designsWhen products are developed for use in many geographic areas, they must meet several locations' requirements. For instance, when developing a new off-ridge ventilation product, GAF considers not only how much net free area (NFA) the unit will have, but also the performance characteristics required to meet Florida Building Code, Texas Department of Insurance (TDI), and Miami-Dade standards so the product can be used in areas that adhere to those codes.Why Does GAF Pay Attention to Codes and Requirements?"We want our customers to be confident in the performance of our products not based solely on our word but also on the basis of third-party standards that level set the industry," notes Hershberger. "Codes and testing requirements provide customers with that outside assurance that our products will hold up to the environmental rigors of a specific region or location."For example, TAS-100(A) tests a product's performance in wind-driven rain. The test provides information on how well a ventilation product will perform in such an environment and helps the product development team learn how likely it is that a ventilation product might leak, so we can then mitigate that risk.How Do Codes Affect Product Quality?Codes may specify what raw materials can be used to make a product or how it will perform in certain standardized tests. For instance, ASTM E108 or ANSI/UL790 Class A roofing fire ratings require a high degree of fire protection to the roof deck, which directly affect the materials used to produce these products. Similarly, the UL 2218 Class 4 impact test or the ASTM E330 Uplift Pressure Test show how a product performs under naturally occurring forces (e.g., hail or wind)"GAF strives to find the balance between performance, strength, and ease of installation (or handleability)," Hershberger says. "This often leads us to develop products that use higher grade materials (better performance over time), are simpler to manufacture with fewer points of potential failure, and are easier to install correctly (ensuring repeatability)."How Codes Affect the Development of High-Quality Roof VentsCreating high-quality roof vents and rooftop accessories didn't occur by accident. The GAF development team focuses on roofing codes and requirements through an intentional design process to drive innovation. From product ideation to design, development, and launch, the team ensures products meet or exceed several codes and standards, including:Florida Building CodeSets minimum performance standards for roof construction, such as wind resistance, fire performance, and roof ventilation requirements. Products must be approved by the state before being installed.Miami-Dade CountyThis county in Florida has some of the strictest building codes in the country due to its classification as a High-Velocity Hurricane Zone. Products used there must also be approved by the county as meeting not only Florida Building Code, but the stricter county requirements.Texas Department of Insurance (TDI)Regulates insurance companies and the insurance/claims process in the state of Texas. Roofing products are evaluated based on TDI-adopted building specifications regarding products used and installation methods.Other tests performed to ensure product performance include:TAS-100(A). Determines the water infiltration resistance of a ridge area ventilation system (ridge vents, static vents, turbines, or powered vents).Simulated snow/ice dam. Ice dams can form when a roof is not properly ventilated, leading to snow melting and refreezing along the lower edge of the roof.UL2218 Class 4 impact test. The UL2218 test is a steel ball drop test that evaluates the impact resistance of roof coverings. Class 4 products are shown to withstand the 20-ft drop of a 2-inch diameter steel ball without cracking through significant damage.Ensuring Roofing Products Are Up to the TaskThe product team at GAF routinely performs these tests to ensure roofing materials meet local roofing code requirements. The company then makes the results publicly available, helping customers nationwide rest assured that they can rely on GAF roofing products to perform as expected.For more information on the GAF ventilation products that meet or exceed code requirements, explore the ridge and off-ridge ventilation offerings.

By Authors Dawn Killough

August 15, 2024

Jeremy Simpson at the 2024 GAF Summit
Residential Roofing

A Day at the GAF Summit with Jeremy Simpson

Protecting what matters most includes promoting the career growth of roofing industry professionals like you. That's why GAF offers a wide range of learning opportunities, including CARE courses, online training, in-person training, and roofing summits and expos.Recently, third generation roofer, Jeremy Simpson of Simpson Roofing Company, spent a day at the GAF Northeast Roofing Summit and Expo to learn more about the latest updates in the residential roofing industry. While the majority of the work the Simpson Roofing Company does is commercial, they are always looking for ways to expand their knowledge by learning about innovative ideas, new products, new software, and new technology in the residential space.Simpson attended breakout sessions on topics including Principles of Ventilation, AI in CRM, and Sales. "I love coming to these GAF summits, because they really line up all the pertinent info for your business to succeed" says Simpson, "I promise you it's worth its weight in gold!"To learn more about on demand, hands-on, and in-person training opportunities through GAF, visit our CARE Contractor Training Center.Video TranscriptMy name is Jeremy Simpson from Simpson Roofing Company. We are out of Vernon, New Jersey, and Patterson, New Jersey, two locations. Today, I'm here at the GAF Summit, and I'm looking to just learn new things. We are a third-generation roofing company. We predominantly do commercial, but all throughout the years, we've done residential. That's why we're here today at this event. We're trying to get updated on the new stuff that's coming out, specifically from GAF. Innovative ideas, new products, new software, new tech. So follow me along today as we explore the GAF summit.[00:00:45]Today, we're going into the principles of ventilation. Designs change, architecture changes, and you need new ways of ventilating. And I don't know all of them. So I want to get some info and see what GAF has to offer as far as new products and new thoughts on how to move the air around. So we just got out of our first breakout session about ventilation. A lot of math, a lot of numbers going into the calculations of moving air around in your attic space to have a really good performed roof system. I didn't know all those details. Now I know, got to use it going forward from there.[00:01:19]I just got out of the AI CRM breakout session there. A little bit of an information overload, and that was a good thing because it really showed me how much I was missing the CRM and AI, it's the future. It's coming.[00:01:37]So I just got out of the third and final breakout of today's GAF Summit, and it was about sales, and it was very interesting to see the different dynamics that take place in the residential market when you're dealing with a homeowner versus something commercial, where oftentimes you don't even get to see who you're selling to. So to find out those little intricacies inside that process was super insightful. The best part of today was everything. I love coming to these GAF summits because they really line up all pertinent information for your business to succeed.[00:02:11]Thank you so much for tagging along today. It was super fun for me. I hope you got a little bit out of it as well. And if you ever find a time to come out to one of these GAF summits, I promise you it's worth its weight in gold.

By Authors GAF Roof Views

July 15, 2024